<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN" "http://www.w3.org/TR/html4/loose.dtd"> <HTML ><HEAD ><TITLE >win32_start_service_ctrl_dispatcher</TITLE ><META NAME="GENERATOR" CONTENT="Modular DocBook HTML Stylesheet Version 1.79"><LINK REL="HOME" TITLE="PHP 手册" HREF="index.html"><LINK REL="UP" TITLE="win32service Functions" HREF="ref.win32service.html"><LINK REL="PREVIOUS" TITLE="win32_set_service_status" HREF="function.win32-set-service-status.html"><LINK REL="NEXT" TITLE="win32_start_service" HREF="function.win32-start-service.html"><META HTTP-EQUIV="Content-type" CONTENT="text/html; charset=UTF-8"></HEAD ><BODY CLASS="refentry" BGCOLOR="#FFFFFF" TEXT="#000000" LINK="#0000FF" VLINK="#840084" ALINK="#0000FF" ><DIV CLASS="NAVHEADER" ><TABLE SUMMARY="Header navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TH COLSPAN="3" ALIGN="center" >PHP 手册</TH ></TR ><TR ><TD WIDTH="10%" ALIGN="left" VALIGN="bottom" ><A HREF="function.win32-set-service-status.html" ACCESSKEY="P" >上一页</A ></TD ><TD WIDTH="80%" ALIGN="center" VALIGN="bottom" ></TD ><TD WIDTH="10%" ALIGN="right" VALIGN="bottom" ><A HREF="function.win32-start-service.html" ACCESSKEY="N" >下一页</A ></TD ></TR ></TABLE ><HR ALIGN="LEFT" WIDTH="100%"></DIV ><H1 ><A NAME="function.win32-start-service-ctrl-dispatcher" ></A >win32_start_service_ctrl_dispatcher</H1 ><DIV CLASS="refnamediv" ><A NAME="AEN239188" ></A ><P > (PECL)</P >win32_start_service_ctrl_dispatcher -- Registers the script with the SCM, so that it can act as the service with the given name</DIV ><DIV CLASS="refsect1" ><A NAME="AEN239191" ></A ><H2 >说明</H2 >bool <B CLASS="methodname" >win32_start_service_ctrl_dispatcher</B > ( string name )<BR ></BR ><P > When launched via the Service Control Manager, a service process is required to "check-in" with it to establish service monitoring and communication facilities. This function performs the check-in by spawning a thread to handle the lower-level communication with the service control manager. </P ><P > Once started, the service process should continue to check-in with the service control manager so that it can determine if it should terminate. This is achieved by periodically calling <A HREF="function.win32-get-last-control-message.html" ><B CLASS="function" >win32_get_last_control_message()</B ></A > and handling the return code appropriately. </P ></DIV ><DIV CLASS="refsect1" ><A NAME="AEN239202" ></A ><H2 >参数</H2 ><P > <P ></P ><DIV CLASS="variablelist" ><DL ><DT ><CODE CLASS="parameter" >name</CODE ></DT ><DD ><P > The short-name of the service, as registered by <A HREF="function.win32-create-service.html" ><B CLASS="function" >win32_create_service()</B ></A >. </P ></DD ></DL ></DIV > </P ></DIV ><DIV CLASS="refsect1" ><A NAME="AEN239212" ></A ><H2 >返回值</H2 ><P > 如果成功则返回 <TT CLASS="constant" ><B >TRUE</B ></TT >,失败则返回 <TT CLASS="constant" ><B >FALSE</B ></TT >。 </P ></DIV ><DIV CLASS="refsect1" ><A NAME="AEN239217" ></A ><H2 >范例</H2 ><P > <TABLE WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" CLASS="EXAMPLE" ><TR ><TD ><DIV CLASS="example" ><A NAME="AEN239220" ></A ><P ><B >例 1. A <B CLASS="function" >win32_start_service_ctrl_dispatcher()</B > example</B ></P ><P > Any text that describes the purpose of the example, or what goes on in the example should go here (inside the </P ><TABLE BORDER="0" BGCOLOR="#E0E0E0" CELLPADDING="5" ><TR ><TD ><code><font color="#000000"> <font color="#0000BB"><?php<br /></font><font color="#007700">if (!</font><font color="#0000BB">win32_start_service_ctrl_dispatcher</font><font color="#007700">(</font><font color="#DD0000">'dummyphp'</font><font color="#007700">)) {<br /> die(</font><font color="#DD0000">"I'm probably not running under the service control manager"</font><font color="#007700">);<br />}<br /><br />while (</font><font color="#0000BB">WIN32_SERVICE_CONTROL_STOP </font><font color="#007700">!= </font><font color="#0000BB">win32_get_last_control_message</font><font color="#007700">()) {<br /> </font><font color="#FF8000"># do some work here, trying not to take more than around 30 seconds<br /> # before coming back into the loop again<br /></font><font color="#007700">}<br /></font><font color="#0000BB">?></font> </font> </code></TD ></TR ></TABLE ></DIV ></TD ></TR ></TABLE > </P ></DIV ><DIV CLASS="refsect1" ><A NAME="AEN239225" ></A ><H2 >参见</H2 ><P > <P ></P ><TABLE BORDER="0" ><TBODY ><TR ><TD ><A HREF="function.win32-get-last-control-message.html" ><B CLASS="function" >win32_get_last_control_message()</B ></A ></TD ></TR ></TBODY ></TABLE ><P ></P > </P ></DIV ><DIV CLASS="NAVFOOTER" ><HR ALIGN="LEFT" WIDTH="100%"><TABLE SUMMARY="Footer navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" ><A HREF="function.win32-set-service-status.html" ACCESSKEY="P" >上一页</A ></TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="index.html" ACCESSKEY="H" >起始页</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" ><A HREF="function.win32-start-service.html" ACCESSKEY="N" >下一页</A ></TD ></TR ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" >win32_set_service_status</TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="ref.win32service.html" ACCESSKEY="U" >上一级</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" >win32_start_service</TD ></TR ></TABLE ></DIV ></BODY ></HTML >